Can a simulation generated from a scan of a real workcell stand in for the robot when a policy is judged? We built a twin of one xArm7 cell and ran five policies through both the twin and the cell: four vision-language-action models deployed zero-shot on an arm they were never trained on, and a language-model agent. Across 520 graded real trials and 8,200 twin episodes, the twin's success rates track the robot's at a mean per-task Pearson correlation of 0.971, a mean maximum rank violation of 0.030 and a mean absolute error of 6.8 percentage points. Each sits inside the range a twin with no error at all would reach, given the sampling noise of the real trials. The twin also predicts which individual real trials succeed, reproduces how policies fail, and replays real motion to separate its own errors from the policy's. Its one systematic error is optimism about off-centre grasps. During these trials the runtime completed about 1,100 episodes per GPU-hour with a 3B-parameter policy in the loop; it now completes about 2,500.
1Introduction
Real-world trials are the reference standard for evaluating a manipulation policy, and they are expensive. Every trial needs an operator to reset the scene and grade the outcome. The estimates are also noisy. With 30 trials, a policy measured at 50% success has a 95% confidence interval of roughly 33 to 67%. Good practice calls for many trials per condition [1], and recent work scales real evaluation by automating resets [2] or by distributing trials across institutions [3]. The cost still grows with every checkpoint, task and site a team wants to compare.
Simulation removes the operator, and its results are useful to the extent that they predict the robot. Whether simulated evaluation predicts real performance was first studied directly for navigation [4]. For manipulation, SIMPLER [5] showed that simulated environments matched to real setups can rank policies consistently with real results, and introduced the mean maximum rank violation (MMRV) to measure ordering errors. Later work has raised the fidelity of these environments and reports sim-to-real correlations between 0.84 and 0.96 [6–16].
Correlation tells a team whether a simulator can be trusted in aggregate. A team training a policy asks narrower questions. Is this checkpoint ready to deploy? Does it improve on the last one? When it fails, where does it fail, and why? The answers matter only if they arrive before the next training run starts, so an evaluation has to be fast as well as accurate.
This report describes a twin generated from a scan of a real workcell and measures it against that cell. We ask five questions:
- Does the twin reproduce real success rates, in ranking and in absolute value?
- How close is that agreement to the limit set by the noise in the real trials?
- Does the twin reproduce what the policy experiences: its own latency, the arm's response and the gripper's behaviour?
- Can it answer questions about a single policy, such as which starts it fails on and how?
- How quickly can it produce those answers?
2Setup
The workcell is a UFactory xArm7 with its stock parallel-jaw gripper, mounted on a bench. An exterior camera stands beside the bench and a second camera is mounted on the wrist; both are calibrated against the robot base. The tasks use four objects: a 28.6 mm cube, a dry-erase marker, a thin-walled cup and a bowl (Table 1). Each task has ten starting layouts, and every real trial and twin episode starts from one of them.
| Task | Object | Target | Layouts | Real VLA success |
|---|---|---|---|---|
| Cube into bowl | 28.6 mm cube | Bowl | 10 | 10–67% |
| Marker into cup | Marker | Cup | 10 | 0–20% |
| Cup into bowl | Cup | Bowl | 10 | 23–67% |
| Marker into bowl | Marker | Bowl | 10 | 7–70% |
We evaluate five policies (Table 2). Four are open vision-language-action models (VLAs) trained on DROID [17], a dataset collected on a Franka arm, and deployed here zero-shot on an arm they were never trained on: π0.5 [18], LAP-3B [19], GR00T N1.7 [20] and MolmoAct2 [21]. The fifth is a language-model agent that operates a perception and motion-planning stack. Every policy runs unmodified in both domains, with the same checkpoint, control rate, step limit and success rule.
Zero-shot transfer makes policies less predictable and pushes real success rates down; 12 of the 16 real VLA cells are below 50%. That makes this a demanding test for a twin, which has to predict policies operating outside their training distribution.
| Policy | Kind | Real trials | Twin episodes |
|---|---|---|---|
| π0.5 | VLA, zero-shot | 30 | 500 |
| LAP-3B | VLA, zero-shot | 30 | 500 |
| GR00T N1.7 | VLA, zero-shot | 30 | 500 |
| MolmoAct2 | VLA, zero-shot | 30 | 500 |
| Agent | Language model with tools | 10 | 50 |
| Total, four tasks | 520 | 8,200 |
Real
Twin
Real
Twin
Real
Twin
Real
Twin3Building the twin
Simulation is usually made useful for robotics by widening it. Domain randomisation varies friction, lighting, masses and controller gains so that the real world falls somewhere inside the simulated distribution [22]. That buys robustness when a policy is trained. When a policy is evaluated it costs resolution, because the measured success rate becomes an average over many environments, none of which is the cell the policy will work in.
We build the twin to match one cell as closely as we can measure it. A policy meets its environment through a few channels: the images from its cameras, the delay between an observation and the resulting action, the arm's response to commands, and the gripper's behaviour when it closes on an object. We measure each channel on the real cell and hold the twin to it. Properties that reach the policy through none of these channels matter less, and we spend less effort on them.
The twin is generated from a scan of the cell. The scan provides the room, the bench and the objects, with their appearance. Measurements of the arm, the gripper and the cameras provide the physical and optical parameters, and each episode starts from the object placements measured in the real trial it is paired with. None of the twin's parameters is fitted to policy success rates. Figure 3 shows the loop and the step that closes it. Where the twin and the robot disagree, the disagreement names the next quantity to measure.
4Agreement with the real robot
The twin reproduces real success rates across all twenty policy–task cells (Figure 4). Its rate lies inside the 95% interval of the real rate in 17 of 20 cells, and the mean absolute difference is 6.8 points. Within each task it orders the policies as the robot does, apart from three swaps among closely matched VLAs that Section 7 examines. Per task, the correlation is 0.935 on cube into bowl, 0.994 on marker into cup, and 0.977 on both cup into bowl and marker into bowl.
| Metric | Twin | 95% interval | Perfect twin |
|---|---|---|---|
| Per-task Pearson r, higher is better | 0.971 | 0.915–0.980 | 0.973 |
| Pooled Pearson r, higher is better | 0.967 | 0.918–0.974 | 0.971 |
| Spearman ρ, higher is better | 0.936 | — | — |
| MMRV, lower is better | 0.030 | 0.010–0.077 | 0.016 |
| Mean absolute error, points | 6.8 | 6.0–10.6 | 6.0 |
| Cells inside the real interval | 17 / 20 | — | — |
4.1Against a perfect twin
Agreement metrics are bounded by the precision of the real measurements. A success rate from 30 real trials carries roughly ±17 points of sampling error, so even a twin that reproduced every cell's true rate exactly would score below r = 1 and above an MMRV of 0. To put our numbers on that scale, we simulate such a twin. For each cell we draw a true rate consistent with the real outcomes, sample real and twin outcomes at our trial counts, and compute every metric on the pair.1
Over 4,000 draws, the perfect twin has a mean per-task r of 0.973, an MMRV of 0.016 and a mean absolute error of 6.0 points. Each of our measured values lies within its 10th–90th percentile range (Figure 5). At these trial counts the aggregate metrics cannot tell our twin apart from one with no error at all. The cell-level analysis in Section 7 can, and it finds one systematic bias.
4.2Comparison with published evaluations
Figure 6 places these results among published twin and simulation evaluations [5–16]. Our per-task and pooled correlations are the highest reported. Our absolute error is lower than that of every work that reports one or publishes the rates needed to compute it, with the exception of ReVeal [9] at 5.0 points. Where a work publishes per-cell rates, we recomputed its error with our own metric code.2
The designs differ in ways that matter. The other evaluations run policies on the robot they were trained or fine-tuned for. Ours run zero-shot on a new arm, where real success rates are lower and harder to predict. Our policy set also includes an agent whose near-perfect real success widens the range of rates within each task, which raises the correlation any twin can reach. Figure 6 places our numbers in context; a controlled comparison would need the same robot, policies and trial counts.
5Matching what the policy experiences
The agreement in Section 4 depends on the twin reproducing the channels through which a policy meets the world. Two of them are routinely left out of simulated evaluation: the policy's own latency, and the detailed behaviour of the gripper.
5.1Latency
A 3B-parameter policy takes a measurable time to respond, and the environment does not pause while it does. Across our real sessions, the median round trip from observation to action ranged from 227 to 1,120 ms, depending on the policy and its serving path. A simulator that returns each action instantly is evaluating a faster policy than the one that will be deployed. In the twin, each action chunk is held for the round trip measured in the real session it is paired with. Figure 7 shows how much of an episode this delay can occupy.
5.2Gripper, arm and cameras
Whether a marginal grasp holds depends on how fast the jaws close, how hard they squeeze, and where they come to rest on each object. We measured these on the real gripper and hold the twin to the result, together with the arm's kinematics, the cameras and the object dimensions (Table 4). None of these measurements involves a policy, so they test the twin independently of the success rates it later predicts.
| Channel | Measurement | Twin | Real cell |
|---|---|---|---|
| Gripper | Empty close, 10–90% | 0.332 s | 0.331 s |
| Squeeze force, 6–70 mm objects | 26–30 N | 30 N rated | |
| Closure holding the marker | 0.836 | 0.83–0.84 | |
| Closure holding the cup | 0.962–0.971 | ≈ 0.97 | |
| Arm | Kinematic error against the controller, 95th percentile | < 1 mm | 5.5 mm stock model |
| Objects | Cube size in the exterior camera, relative to real | 1.046 | 1 |
| Cup size, measured by the agent's perception | 85 × 110 mm | 87 × 111 mm | |
| Bench height at gripper touch-off | −15.5 mm | −13.3 to −17.3 mm | |
| Images | Start frames, median PSNR and SSIM over 45 pairs | 26.8 dB, 0.91 | — |
| Rendered robot against the real image, median | 2.8 px | — | |
| Starts | Placed objects against real start frames, median IoU per session | 0.67–0.94 | — |
| Latency | Round trip held per action chunk | paired session | 227–1,120 ms |
5.3Replaying real motion
To separate errors in the twin's physics from errors in the policy, we replay logged joint trajectories from real trials into the twin, open loop, starting from each trial's measured placements, and grade the result with the task's success rule. This tests the gripper, the contacts and the object models together. On a fixed set of 60 real trials from two tasks, the twin reproduced 17 of 25 real successes and produced no success from any of the 35 real failures. Over 478 real VLA trials, it reproduced 115 of 148 successes and turned 12 of 330 failures into successes (Figure 8).
Replay also makes the twin diagnostic. If a replay diverges from the real outcome, the discrepancy lies in the twin's physics. If the replay agrees and the closed-loop outcome does not, the policy responded differently to what it saw. Each case points to a different fix.
6Answers about a specific policy
6.1Which starts a policy fails on
An aggregate success rate does not say where a policy fails. Because the twin runs each VLA 50 times on every layout, each layout receives its own success rate (Figure 9a). Some structure is shared: two layouts of marker into bowl defeat every VLA. Other structure separates policies. On cup into bowl, LAP-3B almost never succeeds from layouts 1 and 5, while π0.5 succeeds from them in 18 and 21 of 50 episodes.
We test whether these per-layout rates predict individual real trials. For each real VLA trial we take the twin's success rate on that trial's layout and ask whether it separates real successes from real failures within the same cell. A real success has the higher twin rate in 75.4% of within-cell success–failure pairs, an AUC of 0.754 over 15 cells (MolmoAct2 never succeeded on marker into cup). Shuffling layouts within each cell gives 0.50, and none of 5,000 shuffles reached the observed value.
Two baselines that do not use the policy's own twin rate perform worse (Figure 9b). The other VLAs' twin rates on the same layout give an AUC of 0.700, and the other policies' real outcomes on that layout, which require no twin, give 0.642. Most of the signal is which layouts are hard in general, and the twin estimates this better than the real results of other policies do. Part of the signal is specific to the policy being evaluated.
6.2How a policy fails
Where the twin and the robot agree on whether a policy succeeds, they often agree on how it fails. On cube into bowl, MolmoAct2 frequently grasps the cube, lifts it and never releases it, and the paired twin episodes show the same behaviour (Figure 10). For a team developing this policy, that says more than a 30% success rate. On this arm the policy reaches and grasps reliably; what it lacks is the release.
Paired episodes also show where the twin errs. In the GR00T N1.7 example, the twin grasps the cube and places it in the bowl, while on the real robot the gripper closes beside the cube. A single pair does not establish a cause, but this cell is one of the three the twin over-predicts, which we examine next.
7Where the twin and the robot disagree
Three VLA cells fall outside the real 95% interval, and all three are over-predictions (Figure 11): π0.5 on cube into bowl (twin 81.8%, real 67%), GR00T N1.7 on the same task (34.2% against 10%) and GR00T N1.7 on marker into bowl (45.0% against 27%). Tracing the first gripper closure of each cube-into-bowl episode shows that the twin holds the cube in off-centre grasps that fail on the real gripper. The least precise policy, GR00T N1.7, gains the most from this.
The rankings contain three violations, all among the VLAs. On cube into bowl, the over-prediction places GR00T N1.7 above MolmoAct2, whose real rate is higher (30% against 10%). On marker into cup and on cup into bowl, the twin swaps π0.5 and LAP-3B, whose real rates differ by two trials and one trial respectively. Swaps between policies this close arise from real-trial noise alone, which is why even the perfect twin's expected MMRV is 0.016.
The twin scores the agent at 96–100%, and the real agent succeeded in all 40 graded trials. The twin's two agent failures came from a single layout, where the agent's perception misjudged the cup's size from the exterior view and closed the gripper on the rim.
The bias has a physical cause, and the loop in Figure 3 turns it into the next measurement: how the real jaws hold an object gripped off-centre. Until the twin reproduces that, its success rates for policies with imprecise grasps read high, by up to 24 points in the worst cell.
8Throughput
An evaluation that agrees with the robot is useful in proportion to how quickly it returns. During these trials our evaluation runtime completed about 1,100 episodes per GPU-hour on a single RTX PRO 6000 with π0.5, a 3B-parameter VLA, in the loop; it has since reached about 2,500, as described in the whitepaper. Each episode includes physics, rendering of both cameras from the reconstructed cell, policy inference and a full state trace. The runtime is deterministic. An episode produces the same result on every node with the same GPU model, so any result can be reproduced exactly.
The simulation stack underneath it is faster than the reference stacks on their own published benchmarks, at their settings and on the same GPU (Figure 12). We checked behaviour by running the same trained policy through both stacks from the same starts.3
Throughput converts directly into statistical precision. Thirty real trials determine a success rate to about ±17 points; 500 twin episodes determine the twin's rate to about ±4 points in under half a GPU-hour. More episodes shrink the twin's sampling interval but leave any bias in place. Figure 13 shows both cases. On cup into bowl, the twin's estimate for π0.5 converges inside the real interval. On cube into bowl, its estimate for GR00T N1.7 converges, with high confidence, to a rate the robot does not reach.
9Discussion
Evaluation. Agreement at this level qualifies the twin for use. What a team uses day to day is more specific: a success rate for each checkpoint with a stated error, a map of the layouts a policy fails on, and paired episodes that show how it fails. The twin produces these for every checkpoint of a training run, against a specific site, with no operator.
Training. The properties that make the twin a reliable evaluator are matched latency, arm response and grasp behaviour. A training environment needs the same properties for improvements made in simulation to carry over to the robot. A twin that identifies the layouts a policy fails on can also direct data collection and compute toward them, which is the subject of our next study.
Prospective evaluation. Fast, deterministic evaluation makes it practical to commit predictions before the robot runs and grade them afterwards. We ran one such round with an earlier twin, and its record is public.
10Limitations
- Calibrated against the real cell. The twin was calibrated to measurements of the real cell, and its episodes start from placements measured in the real trials. Its parameters were not fitted to success rates, but the evaluation was not blind to the real data. A prospective test, with predictions fixed before any real trial, is the next step.
- Optimistic on imprecise grasps. The twin holds off-centre grasps that the real gripper loses, which accounts for all three cells outside their intervals.
- The agent widens the range. The agent succeeded in every graded real trial while most VLA cells sit below 50%, which raises the correlation a twin can reach within each task. Appendix A lists every cell, so agreement on any subset of policies can be recomputed.
- Unmodelled events. The twin has no controller faults, camera dropouts or operator interventions.
- Scale. One workcell, one arm, four tasks and five policies, with 30 real trials per VLA cell and 10 per agent cell. Real VLA rates on marker into cup span only 0–20%.
Appendix A. Success rates for every cell
| Policy | Cube into bowl | Marker into cup | Cup into bowl | Marker into bowl |
|---|
Notes
- Confidence intervals come from 2,000 bootstrap resamples in which the trials of every cell are resampled with replacement in both domains. For the perfect twin, each cell's true rate is drawn from Beta(k+1, n−k+1) given its real outcomes, and real and twin outcomes are drawn from binomials at the real and twin trial counts. MMRV follows SIMPLER [5]: for each policy, the largest real gap to any policy it is mis-ordered against, averaged over policies and then over tasks. ↩
- SimFoundry [7] publishes real and simulated rates for every cell. Assuming 25 trials per cell, our code reproduces its published per-task correlation of 0.911 and MMRV of 0.018, and gives a pooled correlation of 0.813 and a mean absolute error of 17.2 points. On its zero-shot tasks alone, the same code gives 0.918, 0.950 and 8.8 points. SIMPLER, RoboSnap and SO-101 Bench errors are recomputed the same way from their published per-cell results. ↩
- Isaac Lab 3.0, Franka lift: 801,206 against 439,363 environment steps per second, physics only, 8,192 worlds on an RTX PRO 6000. Kuka-Allegro lift with a 64 × 64 camera per world: 275,485 against 203,448. Against Isaac Lab's published RTX-rendered camera row, with its materials: 264,046 against 154,396. Isaac Lab's own trained policy, run from Isaac Lab's starts in both stacks, agrees to within one point. ManiSkill3 PickCube at equal behaviour: 1.63× at 4,096 worlds, 2.04× at 8,192 and 3.19× at 16,384. Splat rendering: 4,096 worlds of four articulated assets in a 1.15M-Gaussian room, two cameras each, on an H100; 5.4× at 640 × 480 and 26.8× at 128 × 128. ↩
References
- H. Kress-Gazit et al. Robot Learning as an Empirical Science: Best Practices for Policy Evaluation. arXiv:2409.09491, 2024.
- Z. Zhou et al. AutoEval: Autonomous Evaluation of Generalist Robot Manipulation Policies in the Real World. arXiv:2503.24278, 2025.
- P. Atreya et al. RoboArena: Distributed Real-World Evaluation of Generalist Robot Policies. arXiv:2506.18123, 2025.
- A. Kadian, J. Truong, A. Gokaslan et al. Sim2Real Predictivity: Does Evaluation in Simulation Predict Real-World Performance? IEEE Robotics and Automation Letters, 2020.
- X. Li et al. Evaluating Real-World Robot Manipulation Policies in Simulation. arXiv:2405.05941, 2024.
- A. Jain et al. PolaRiS: Scalable Real-to-Sim Evaluations for Generalist Robot Policies. arXiv:2512.16881, 2025.
- N. Ranawaka et al. SimFoundry: Modular and Automated Scene Generation for Policy Learning and Evaluation. arXiv:2606.28276, 2026.
- S. Zhang et al. RoboSnap: One-Shot Real-to-Sim Scene Generation for Generalizable Robot Learning and Evaluation. arXiv:2607.06699, 2026.
- X. Wang et al. ReVeal: A Reconstruction-Aware Real-to-Sim Framework for VLA Policy Evaluation. arXiv:2609.23910, 2026.
- S. Verma, L. Cilio, V. Christodoulou, T. Fermelis and Q. Ng. Measuring Asset and Scene Reconstruction Effects in Real-to-Sim Robot Evaluation. arXiv:2610.00731, 2026.
- K. Zhang et al. Real-to-Sim Robot Policy Evaluation with Gaussian Splatting Simulation of Soft-Body Interactions. arXiv:2511.04665, 2025.
- T. Hickok. SO-101 Bench: Accessible Spatial Manipulation. arXiv:2610.36420, 2026.
- P. Liu, Y. Liu, S. Guo et al. JoyAI-Sim: A Simulation-Enabled Interconversion Toolchain for the Embodied Data Pyramid. arXiv:2606.16776, 2026.
- G. Chen, Q. Xia, J. Peng et al. Agentic Real2Sim: Physics-based World Modeling with Vision-Language Agents. arXiv:2607.19190, 2026.
- L. Ruan, J. Yang, S. Gao et al. X2Real: An eXtensive Simulation Benchmark for Real-World Generalist Policies. arXiv:2609.27449, 2026.
- Y. Kim, W. Pumacay, O. Rayyan et al. MolmoSpaces: A Large-Scale Open Ecosystem for Robot Navigation and Manipulation. arXiv:2602.11337, 2026.
- A. Khazatsky et al. DROID: A Large-Scale In-The-Wild Robot Manipulation Dataset. arXiv:2403.12945, 2024.
- Physical Intelligence, K. Black et al. π0.5: a Vision-Language-Action Model with Open-World Generalization. arXiv:2504.16054, 2025.
- L. Zha et al. LAP: Language-Action Pre-Training Enables Zero-shot Cross-Embodiment Transfer. arXiv:2602.10556, 2026.
- NVIDIA, J. Bjorck et al. GR00T N1: An Open Foundation Model for Generalist Humanoid Robots. arXiv:2503.14734, 2025.
- H. Fang et al. MolmoAct2: Action Reasoning Models for Real-world Deployment. arXiv:2605.02881, 2026.
- J. Tobin, R. Fong, A. Ray, J. Schneider, W. Zaremba and P. Abbeel. Domain Randomization for Transferring Deep Neural Networks from Simulation to the Real World. IROS, 2017.
- E. B. Wilson. Probable Inference, the Law of Succession, and Statistical Inference. Journal of the American Statistical Association, 1927.
Citation
@misc{blobit2026twin,
title = {A Digital Twin Generated from a Scan Predicts Real-World
Success Rates of Robot Manipulation Policies},
author = {{Blobit Research}},
year = {2026},
month = nov,
url = {https://www.blobit.ai/research/real-to-sim-to-real}
}